EWDB

Integrated Servodrive

Featuring an integrated drive control unit, this synchronous servomotor combines compact dimensions with space-saving machine design and optimized wiring.

Features

  • Power Supply from 24 to 60 Vdc
  • Integrated Single-turn Absolute Encoder
  • Available Field Buses: CANopen DS402 – EtherCAT – ProfinetIO – EthernetIP
  • 4 Digital Inputs
  • Protection Level: IP65
  • Configuration with Drivewatcher
  • 4 IP65 Industrial Metal Connectors Water-resistant on the Rear, 2 on Top for Field Bus Communication and 2 on Bottom for I/O and Power Connections
  • Based on Motors with 60 mm Flange, Stall Torque of 0.7 Nm, 1.3 Nm, or 1.6 Nm with or without Integrated Gearbox

EWDB

Scarica pdf

EWDB121xxxEWDB122xxxEWDB123xxx
Drive section
Input Power Main Circuit From 24Vdc to 60Vdc – All data referred to 48Vdc +/-10%From 24Vdc to 60Vdc – All data referred to 48Vdc +/-10%From 24Vdc to 60Vdc – All data referred to 48Vdc +/-10%
Input Power Control Circuit24Vdc24Vdc24Vdc
Output Current10A10A10A
Peak Current (for 2 s) 20A20A20A
Control MethodPWM Sinusoidal wave drivePWM Sinusoidal wave drivePWM Sinusoidal wave drive
Analogue Inputnonono
Digital Input4 x +24 Vdc (Drive Enable – Limit Switch 1, 2 – Homing) 4 x +24 Vdc (Drive Enable – Limit Switch 1, 2 – Homing)4 x +24 Vdc (Drive Enable – Limit Switch 1, 2 – Homing)
Digital Outputnonono
Status LedFor status and alarms warningFor status and alarms warningFor status and alarms warning
CommunicationRS-485 (for configuration) – CANopen – EtherCAT - ProfinetIORS-485 (for configuration) – CANopen – EtherCAT - ProfinetIORS-485 (for configuration) – CANopen – EtherCAT - ProfinetIO
ProtectionI²T, thermalI²T, thermalI²T, thermal
Brake managementIntegrated; immediate stop or in ramp mode (optional)Integrated; immediate stop or in ramp mode (optional)Integrated; immediate stop or in ramp mode (optional)
Configuration driveWith Drivewatcher SoftwareWith Drivewatcher SoftwareWith Drivewatcher Software
Power Loss 7,2W @ stand-by – 24,3W @ I nominal7,2W @ stand-by – 24,3W @ I nominal7,2W @ stand-by – 24,3W @ I nominal
Motor Section
Stall Torque0,7 Nm1,3 Nm1,6 Nm
Max Torque2,4 Nm2,5 Nm3,5 Nm
Stall Current7A10A14A
Peak Current20A20A20A
Max Mechanical Speed3500 rpm3000 rpm3000 rpm
Voltage Constant Ke8 V/krpm8 V/krpm8,5 V/krpm
Torque Constant KT0,13 Nm/A0,132 Nm/A0,141 Nm/A
Rotor Inertia0,13 kgcm²0,23 kgcm²0,33 kgcm²
FlangeInterax 63 mm x Centering 40 mm
Weight1,8 kg2,3 kg2,9 kg
Connection TypeConnectors M17 for power and M12 for signal / fieldbusConnectors M17 for power and M12 for signal / fieldbusConnectors M17 for power and M12 for signal / fieldbus
Environmental Conditions
Working Temperature0°C to 40°C0°C to 40°C0°C to 40°C
Stocking Temperature-20°C .. + 65°C-20°C .. + 65°C-20°C .. + 65°C
AltitudeLower than 1000mLower than 1000mLower than 1000m
Humidity5 to 85%RH or less both Operating and Storage5 to 85%RH or less both Operating and Storage5 to 85%RH or less both Operating and Storage
Vibration9,8m/s² or less, 10 - 60Hz (Do not use continuously at resonance frequency9,8m/s² or less, 10 - 60Hz (Do not use continuously at resonance frequency9,8m/s² or less, 10 - 60Hz (Do not use continuously at resonance frequency
Protection DegreeIP65IP65IP65
Standard
2014/35/UE - 2014/35/EUDirettiva Bassa Tensione / Low Voltage Directive / Directive Basse Tension /
Niederspannungsrichtlinie / Directiva de Baja Tensión:
Direttiva Bassa Tensione / Low Voltage Directive / Directive Basse Tension /
Niederspannungsrichtlinie / Directiva de Baja Tensión:
Direttiva Bassa Tensione / Low Voltage Directive / Directive Basse Tension /
Niederspannungsrichtlinie / Directiva de Baja Tensión:
2014/30/UE - 2014/30/EUDirettiva EMC / EMC directive / Directive CEM / EMV-Richtlinie / Directiva EMC:Direttiva EMC / EMC directive / Directive CEM / EMV-Richtlinie / Directiva EMC:Direttiva EMC / EMC directive / Directive CEM / EMV-Richtlinie / Directiva EMC:
2011/65/UE – 2011/65/EUDirettiva RoHS / RoHS Directive / Directive RoHS / RoHS-Richtlinie / Directiva RoHS:Direttiva RoHS / RoHS Directive / Directive RoHS / RoHS-Richtlinie / Directiva RoHS:Direttiva RoHS / RoHS Directive / Directive RoHS / RoHS-Richtlinie / Directiva RoHS:
CEI EN 61800-3 2005 + A1:2013EMC requirements and specific test methodsEMC requirements and specific test methodsEMC requirements and specific test methods
CEI EN 61800-2 1999-2009General requirements. Rating specificationsGeneral requirements. Rating specificationsGeneral requirements. Rating specifications
CEI EN 61800-5-1 2009Safety requirements. Electrical, thermal and energySafety requirements. Electrical, thermal and energySafety requirements. Electrical, thermal and energy